Do you have questions?

We are happy to assist you!

Please call us on »

Bürkert - Close to you
Office /6
    • Main Office
      Burkert Contromatic Australia Pty. Limited
      15 Columbia Way
      Norwest Business Park
      Baulkham Hills, NSW 2153

      PO Box 6524
      Baulkham Hills NSW 2153
      Phone +61 1300 888 868
      Fax +61 1300 888 076
      E-Mail fnyrf.nh@ohexreg.pbz
    • Office
      South Australia
      Innovation House
      First Avenue
      Mawson Lakes SA 5095

      E-Mail fnyrf.nh@ohexreg.pbz
    • Office
      Bürkert Perth
      Unit 8, 1st Floor
      85 Reid Promenade
      Joondalup WA 6027

      E-Mail fnyrf.nh@ohexreg.pbz
    • Office
      Bürkert Brisbane
      Unit 5a, 88 Brandl Street
      Brisbane Technology Park
      Eight Mile Plains QLD 4113

      E-Mail fnyrf.nh@ohexreg.pbz
    • Office
      Bürkert Melbourne
      Suite 49, UniPark
      Building 4, 195 Wellington Road
      Clayton VIC 3168

      E-Mail fnyrf.nh@ohexreg.pbz
    • Office
      Bürkert Sydney
      15 Columbia Way
      Norwest Business Park
      Baulkham Hills NSW 2153

      E-Mail fnyrf.nh@ohexreg.pbz
  • Main Office
  • Headquarters
  • Systemhaus
  • Distributor
  • Office
  • Plant
  • Logistic center
bürkert
We make ideas flow.
We make ideas flow.

    Type 8222 - Conductivity meter

    Produkt-Foto Typ 8222

    The depiction of the products may differ from the actual specific design.

    • Produkt-Foto Typ
    • Produkt-Foto Typ 8222
    • Produkt-Foto Typ 8222
    • Ersatzteil-Zeichnung Bürkert
    • Ersatzteil-Zeichnung Bürkert
    • Ersatzteil-Zeichnung Bürkert

    Type Description

    The Bürkert compact meter Type 8222 is designed for measuring the conductivity of fluids. The conductivity meter consists of a sensor, plugged-in and pined to the transmitter (with removable display). The sensor comprises a cell with two electrodes and a Pt1000 temperature probe. The sensor itself is available with three different cell constants C, these with C=0.01 or 0.1 are fitted with stainless steel electrodes and those with C=1.0 are fitted with graphite electrodes. The conductivity meter can operate independent of the display but it will be required for programming the device and also for visualizing continuously the measured and processed data. The device Type 8222 is available: - with three fully programmable outputs: two transistor and one 2-wire 4...20 mA current outputs - with four fully programmable outputs: two transistor and two 3-wire 4...20 mA current outputs. The transmitter converts the measured signal, displays different values in different physical units (if display mounted) and computes the output signals, which are provided via one or two M12 fixed connectors.

    • Perfect for clean water and slightly concentrated liquids
    • Integral device for direct connection to PLC
    • Simulation of process values for diagnostics
    • Three cell constants to cover a wide application range e.g. reverse osmosis

    For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

    Downloads

    Data Sheets

    Description
    Filesize
    Language / Country
    DTS Type 8222 data sheet | conductivity meter [ELEMENT neutrinoversion] 1.1 MB EN / EU
    DTS Type 8222 data sheet | conductivity meter [ELEMENT version;US units] 908.6 kB EN / US
    DTS Type 8222 data sheet | conductivity meter [ELEMENT version] 548.3 kB EN / EU
    DTS Type S022 data sheet | fitting for ELEMENT pH/resistive conductivity measurement devices 933.3 kB EN / EU
    DTS Tipo 8222 hoja de datos | transmisor de conductividad 2 MB ES / ES
    DTS Typ 8222 Datenblatt | Leitfähigkeitsmessgerät [ELEMENT neutrino-Ausführung] 1 MB DE / DE
    DTS Typ 8222 Datenblatt | Leitfähigkeitsmessgerät [ELEMENT-Ausführung] 2 MB DE / DE
    DTS Typ S022 Datenblatt | ELEMENT-Fitting für pH- und konduktive Leitfähigkeitsmessgeräte 933.8 kB DE / DE
    DTS Type 8222 fiches techniques |Conductivimètre [conception ELEMENT neutrino] 1.1 MB FR / FR
    DTS Type 8222 fiches techniques |Conductivimètre [conception ELEMENT] 535.5 kB FR / FR

    User Manuals

    Description
    Filesize
    Language / Country
    MAN Accessory Type 8026 8036 SE368202 8222 8228 ELEMENT | Display module 808.4 kB EN,FR,DE / EU
    MAN Op. Instr. 8222 neutrino 1.3 MB EN / EU
    MAN Operating Instr. Type S022 | Fitting for 8202 and 8222 ELEMENT, 8202+8222 ELEMENT neutrino 2.1 MB EN,FR,DE / EU
    MAN Operating Instructions Type 8222 ELEMENT | Conductivity meter 2.8 MB EN / EU
    MAN Quickstart Type 8202 8222 ELEMENT | Leitfähigkeits-Messgerät 6.1 MB EN,FR,DE / EU
    MAN Service manual Type 8222 ELEMENT neutrino | Gasket replacement 177.1 kB EN,FR,DE / EU
    MAN Service manual Type 8202 8222ELEMENT neutrino | Gasket forthe connecting box 145.4 kB EN,FR,DE / EU
    MAN Bedienungsanleit 8222 neutrino 1.2 MB DE / EU
    MAN Bedienungsanleitung Typ 8222 ELEMENT | Leitfähigkeitsmessgerät 2.7 MB DE / EU
    MAN Manuel 8222 neutrino 2.3 MB FR / EU
    MAN Manuel d?utilisation Type 8222 ELEMENT | Conductivimètre 2.9 MB FR / EU

    EU Declaration

    Description
    Filesize
    Language / Country
    ABD EU-DoC|EU Declaration 462.5 kB ML

    Interactive Animation

    Description
    Filesize
    Language / Country
    3D_ANIMATION 3D-Animation - 8222 2.7 MB DE
    3D_ANIMATION 3D-Animation - 8222 2.7 MB EN

    Flyers and Catalogues

    Description
    Filesize
    Language / Country
    MISC Analytical Meters 587.3 kB EN / EU

    Available products

    14 Hits
  • Filter
    • Perfect for clean water and slightly concentrated liquids
    • Integral device for direct connection to PLC
    • Simulation of process values for diagnostics
    • Three cell constants to cover a wide application range e.g. reverse osmosis